Fire Protect 2 SB (Heat/Smoke/CO)
Home Automation
Wireless combined heat, smoke, and CO detector with sealed batteries
PAN India — B2B Distribution Network
| Communication | |
|---|---|
| Jeweller communication technology | Proprietary wireless communication technology to transmit commands, alarms, and events. Key features:
Learn More |
| Frequency band | 865.0–867.0 MHz |
| Maximum effective radiated power (ERP) | up to 20 mW
Automatic power control to reduce power consumption and radio interference. |
| Radio signal modulation | GFSK |
| Radio communication range | up to 1,700 m Between the device and a hub (or a range extender) in an open space. Calculate radio communication range at the facility |
| Encrypted communication | All stored and transmitted data are protected by block encryption featuring a dynamic key. |
| Frequency hopping |
To prevent radio interference and jamming. Learn More |
| Sensitive elements | |
|---|---|
| Sensitive elements | smoke sensor heat sensor CO (carbon monoxide) sensor |
| Smoke detection | |
|---|---|
| Sensitive element | double-spectrum optical sensor
Recognizes smoke by the size of particles in the air. |
| Protection from false alarms | Does not react to water vapor. |
| Patented smoke chamber | Protects the smoke sensor from dust, dirt, and insects. |
| Dangerous temperature detection | |
|---|---|
| Sensitive element | according to the requirements for Class A1R heat detectors Requirements of EN 54-5 and BS 5446-2 standards. |
| High temperature alarm | at temperatures above 64°C |
| Temperature spike alarm | when the temperature rises more than 10°C in 1 minute or less |
| Carbon monoxide (CO) detection | |
|---|---|
| Sensitive element | chemical CO sensor |
| Alarm if accumulated dose of CO is exceeded | more than 50 ppm (0.005%) — no more than in 90 minutes more than 100 ppm (0.01%) — no more than in 40 minutes more than 300 ppm (0.03%) — no more than in 3 minutes CO concentration of 400 ppm (0.04%) within 3 hours can be life-threatening. The detector stops notifying about the dangerous level of carbon monoxide when the concentration drops to 50 ppm (0.005%) within one minute. |
| Sensor life | 10 years
After 10 years of operation, the detector must be replaced with a new one. |
| Additional features | |
|---|---|
| In-built siren | volume 85 dB at a distance of 3 meters
Sound notification of alarms. Active until the reason for triggering is eliminated or until the user disables notification. |
| Interconnected fire detectors alarms | via primary interconnection
If one of the fire detectors in the system detects a threat, it sends an alarm to the hub. Within 20 seconds, the hub initiates an interconnected alarm and sends data to Ajax apps. via fallback interconnection1At the same time with notifying the hub, the initiating detector sends an alarm directly to other detectors. All connected detectors activate the buzzer within a minute. It will work even in the worst-case scenario of losing connection with the hub. Learn More1 Fallback interconnected alarm is available only for FireProtect 2 detectors with firmware version 5.59.2.ХХ or later. Devices that support the fallback interconnected alarm are marked on the package with a “Fallback interconnect supported” label. |
| LED indication | green is a power indication
A LED indicator on the device enclosure lights up once every 56 seconds. The indication meets the requirements of EN 50291. yellow is an indication of malfunctionsA LED indicator on the device enclosure lights up when malfunctions are detected. For example, if the battery is low. red is an indication of fire alarmsA LED indicator on the device enclosure lights up when the detector registers a fire alarm. |
| Button on the front panel of the detector | In normal mode, runs the detector test when pressed. In the event of an alarm or malfunction, the pressing turns off the detector sound notification. |
| Anti-sabotage protection | |
|---|---|
| Tampering alarm | Alerts of attempts to detach the detector from the surface or remove the mounting panel. Learn more |
| Protection against spoofing | device authentication |
| Detection of communication failure | within 15 minutes The time to detect communication loss depends on the settings for the number of undelivered data packages (specified in the Jeweller or Jeweller/Fibra settings). The polling interval is fixed at 300 seconds. Learn More |
| Power supply | |
|---|---|
| For FireProtect 2 SB (Heat/Smoke/CO) | 2 non-replaceable lithium batteries
10 years of battery life. |
| Enclosure | |
|---|---|
| Dimensions | 124 × 124 × 45 mm |
| Weight | 270 g |
| Operating temperature range | from 0°С to +50°С |
| Operating humidity | up to 80% |
| Protection class | IP20 |
| Complete set | |
|---|---|
| Complete set |
FireProtect 2 SB (Heat/Smoke/CO) Jeweller SmartBracket mounting panel Installation kit Quick start guide |
| Additional information | |
|---|---|
| Compliance with standards | Learn more |
| User manual | Learn more |
| Warranty | 24 months Learn more |